Home > Online water quality electrode > online ammonia nitrogen detector
Products
  • Water Quality Sensor
  • Water Quality Testing
  • Online water quality electrode
  • Buoy Shore Station Series
  • online ammonia nitrogen detector

    The ammonia nitrogen concentration was measured by the ion-selective electrode method. The ammonia ion selection electrode directly detects the ammonium ion in the water environment to determine the concentration of ammonia nitrogen. The pH electrode was used as the reference electrode to obtain better stability.Because the dissolution of the measurement result of the sensor is disturbed by the potassium ion, so when the concentration of the potassium ion in the water is high, the potassium ion compensation is needed.

    measuring principle

    The ammonia nitrogen concentration was measured by the ion-selective electrode method. The ammonia ion selection electrode directly detects the ammonium ion in the water environment to determine the concentration of ammonia nitrogen. The pH electrode was used as the reference electrode to obtain better stability.

    Because the dissolution of the measurement result of the sensor is disturbed by the potassium ion, so when the concentration of the potassium ion in the water is high, the potassium ion compensation is needed.

    Ammonia nitrogen sensor consists of ammonium ion selective electrode, potassium ion (optional), pH electrode and temperature electrode. These parameters can correct the measurement value of ammonia nitrogen to each other and realize multi-parameter measurement.

     

    functional characteristics

    Digital sensor, strong anti-interference ability, the transmission distance is long;

    Standard digital signal output, which can be integrated and networked with other devices without a transmitter;

    Sensor site installation is convenient and fast, to achieve plug and play;

    Sensor power supply positive and negative electrode reverse connection protection, sensor RS485 A / B terminal misconnection power supply protection;

    Simple use, reliable results, interface operation instructions can reduce operation errors;

    Set up a visual alarm system to provide important alarm functions;

    The controller can achieve wall mounting / panel mounting / clip mounting.

     

    Typical application

    Monitor the nitrification treatment, aeration tank, industrial processes and ammonia nitrogen values in river water.

    Sensing technical parameter
    measuring range(NH4N):0.1~1000 mg/L
    (NO3N):0.5~1000 mg/L
    (K+):0.5~1000 mg/L
    (CL-):3~1000 mg/L
    (F-):0.5~1000 mg/L
     PH:5-10     tempreture:0~40℃
    resolution ratioIon parameters:0.01mg/L
    tempreture:0.1℃
    ph:0.01
    measurement accuracyOther ion parameters :± 10% of the measured value or ±0.2 mg/L Temperature :± 0.5℃ pH:±0.1 pH
    repeatability±5% or 0.2mg/1 Max
    communication protocolMODBUS RS485
    storage temperature0 to 50 ° C (no freezing)
    working temperature0 to 40 ° C (no freezing)
    size55mm×342mm(diameter × length)
    weight<1KG
    level of protectionIP68/NEMA6P
    cable length0 m cable is standard and can be extended up to 100 m


    Controller parameters

    ModelMDS-KP500
    Display4.3 inches, 480*800 resolution, 262K color, IPS screen, wide viewing Angle, with backlight

    Capacitive touch screen with three protection processes (moisture-proof, mildew proof, salt spray proof)
    Display size95.0mm*53.9mm
    Measuring range-99999.0000~99999.0000
    Password ProtectionThe default password is 0000
    Compatible sensorDigital sensor
    Mounting methodDisk mounting (with chassis), wall-mounted mounting
    Alarm relay2 relays can set high and low alarm
    Current output2 isolated 4-20mA, maximum load 750Q, can be set
    Communication portRS485 Modbus RTU
    Memory backupAll user Settings are stored indefinitely in EERPOM
    historical dataThe storage capacity of 8000 points is recorded at a 5-minute interval
    Operating environment-10~+50℃,0~95% relative humidity, no condensation
    Storage environment-20 to +70 ° C,0 to 95% relative humidity, non-condensing
    The power supply12V±10%
    Power consumption of the instrumentless than 6W
    Instrument size144X145X85(mm)
    Protection classIP65





    WeChat MADSUR